Abstract
The corrosion resistance of cerium-based conversion coatings was evaluated using a ~50 μm diameter capillary probe. The tests showed three distinct regions during electrochemical impedance spectroscopy and potentiodynamic testing: active, intermediate, and passive. Active regions had total impedance values of less than 200 Ω·cm 2 and corrosion current densities (i corr ) greater than 1x10 -4 Amps/cm 2 . Passive regions had total impedance values greater than 10 KΩ·cm 2 and i corr values less than 1x10 -5 Amps/cm 2 . The total impedance and i corr values for intermediate regions were between those for active and passive regions. Both active and intermediate regions displayed mixed open circuit potentials ranging from -0.50 V to -0.85 V vs. SCE, which showed that the coatings were susceptible to galvanic corrosion. The ability to isolate and probe specific surface features can provide insight into the corrosion mechanism as well as where corrosion is likely to initiate.
| Original language | American English |
|---|---|
| Journal | ECS Transactions |
| Volume | 25 |
| DOIs | |
| State | Published - Jan 1 2010 |
Keywords
- Active regions
- Conversion coatings
- Corrosion current densities
- Corrosion mechanisms
- Galvanic corrosion
- Open circuit potential
- Potentiodynamic testing
- Specific surface
Disciplines
- Materials Science and Engineering
Fingerprint