Skip to main navigation Skip to search Skip to main content

Microelectrochemical Testing of Cerium-Based Conversion Coatings

Research output: Contribution to journal › Article › peer-review

Abstract

The corrosion resistance of cerium-based conversion coatings was evaluated using a ~50 μm diameter capillary probe. The tests showed three distinct regions during electrochemical impedance spectroscopy and potentiodynamic testing: active, intermediate, and passive. Active regions had total impedance values of less than 200 Ω·cm 2 and corrosion current densities (i corr ) greater than 1x10 -4 Amps/cm 2 . Passive regions had total impedance values greater than 10 KΩ·cm 2 and i corr values less than 1x10 -5 Amps/cm 2 . The total impedance and i corr values for intermediate regions were between those for active and passive regions. Both active and intermediate regions displayed mixed open circuit potentials ranging from -0.50 V to -0.85 V vs. SCE, which showed that the coatings were susceptible to galvanic corrosion. The ability to isolate and probe specific surface features can provide insight into the corrosion mechanism as well as where corrosion is likely to initiate.

Original languageAmerican English
JournalECS Transactions
Volume25
DOIs
StatePublished - Jan 1 2010

Keywords

  • Active regions
  • Conversion coatings
  • Corrosion current densities
  • Corrosion mechanisms
  • Galvanic corrosion
  • Open circuit potential
  • Potentiodynamic testing
  • Specific surface

Disciplines

  • Materials Science and Engineering

Fingerprint

Dive into the research topics of 'Microelectrochemical Testing of Cerium-Based Conversion Coatings'. Together they form a unique fingerprint.

Cite this