Abstract
This study investigates temperature distributions in steel-concrete composite slabs subjected to fire using distributed fiber optic sensors. Several 1.2 m × 0.9 m composite slabs instrumented with telecommunication-grade single-mode fused silica fibers were fabricated and subjected to fire for over 3 hours. Temperatures were measured at centimeter-scale spatial resolution by means of pulse pre-pumped Brillouin optical time domain analysis. The distributed fiber optic sensors operated at material temperatures higher than 900 °C with adequate sensitivity and accuracy to allow structural performance assessment, demonstrating their effective use in structural fire applications. The measured temperature distributions indicate a spatially-varying, fire-induced thermal response in steel-concrete composite slab, which can only be adequately captured using approaches that provide high data point density.
| Original language | American English |
|---|---|
| Journal | Proceedings of the 9th International Conference on Structural Health Monitoring of Intelligent Infrastructure: Transferring Research into Practice (2019, St. Louis, MO) |
| Volume | 2 |
| State | Published - Aug 7 2019 |
Disciplines
- Structural Engineering
Fingerprint
Dive into the research topics of 'Measuring Temperature Distribution in Steel-Concrete Composite Slabs Subjected to Fire using Brillouin Scattering based Distributed Fiber Optic Sensors'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS