Abstract
The focus of this paper is on zero-crossing current distortion that commonly occurs in active power factor correction (PFC) circuits. Initially, it derives several equations which quantify the zero-crossing error. Then it proposes a new switching scheme which drastically mitigates the problem. Finally, it shows the effectiveness of the proposed method using simulation results. An H-bridge PFC topology is used.
| Original language | American English |
|---|---|
| Journal | Proceedings of the 4th Annual IEEE Energy Conversion Congress and Exposition (2012, Raleigh, NC) |
| DOIs | |
| State | Published - Sep 1 2012 |
Keywords
- Active Power Factor Corrections
- Current Distortion
- Distortion
- Electric Power Factor
- Energy Conversion
- Exhibitions
- H-Bridges
- Hystersis
- Inductance
- Inductors
- Interference Suppression
- Power Factor Correction
- Power Factor Correction Circuits
- Reactive Power
- Switches
- Switching Scheme
- Topology
- Zero Current Switching
- Zero-Crossings
Disciplines
- Electrical and Computer Engineering
Fingerprint
Dive into the research topics of 'Elimination of Zero-Crossing Distortion in a Power Factor Correction Circuit'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS