Abstract
Electrochemical impedance spectroscopy was used to study the corrosion resistance of Al 7075-T6 after degreasing and one of three different alkaline activations. Electrochemical tests were conducted using an aqueous solution containing 0.35 w/v% NaCl and 0.70 w/v% (NH4)2SO4 at its natural pH of ∼5.5 or with its pH adjusted to ∼9.0. These tests showed increasing the electrolyte pH to 9.0 made the electrolyte less corrosive, which allowed impedance characterization at low frequency (1.00–0.01 Hz) after only 1500 s of stabilization prior to testing. The total impedance of the native oxide was ∼5.9 kΩ cm2 and degreasing did not alter this value. Degreasing followed by activation in 5 wt % Na2CO3 or 1 wt % NaOH decreased the total impedance by ∼20% to 4.8 kΩ cm2, whereas activation in 2 wt % NaOH decreased impedance by ∼30% to 4.2 kΩ cm2. The decreased impedance after activation allowed a cerium-containing solution to penetrate the surface oxide and react with the substrate to form a conversion coating. Thus, increasing the electrolyte pH made the electrolyte less corrosive, which enabled characterization of the decrease in surface oxide impedance after alkaline treatments using electrochemical impedance spectroscopy.
| Original language | American English |
|---|---|
| Pages (from-to) | C296-C301 |
| Journal | Journal of the Electrochemical Society |
| Volume | 158 |
| Issue number | 9 |
| DOIs | |
| State | Published - Jan 1 2011 |
Keywords
- Aluminum Alloys
- Corrosion Resistance
- Corrosion Testing
- Electrochemical Impedance Spectroscopy
- Electrolytes
- Oxidation
- PH
- Surface Treatment
Disciplines
- Materials Science and Engineering
Fingerprint
Dive into the research topics of 'Electrochemical Characterization of Al 7075-T6 Surface Oxide after Alkaline Treatments'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS