Abstract
In this study, a three-dimensional finite element model of the Bill Emerson Memorial cable-stayed bridge was developed and validated with the acceleration data recorded during the M4.1 earthquake of May 1, 2005, in Manila, Arkansas. The model took into account the geometric nonlinear properties associated with cable sagging and soil-foundation-structure interaction. The validated model was used to evaluate the performance of a seismic protective system, the behavior of cable-stayed spans, and the accuracy of two simplified bridge models that have been extensively used by the structural control community. The calculated natural frequencies and mode shapes correlated well with the measured data. Except that the hollow columns of two H-shaped towers were near yielding immediately above their capbeams, the cable-stayed spans behaved elastically as expected under the design earthquake that was scaled up from the recorded rock motions at the bridge site. The minimum factor of safety of all cables is 2.78, which is slightly greater than the design target.
| Original language | American English |
|---|---|
| Journal | Transportation Research Record |
| DOIs | |
| State | Published - Jan 1 2010 |
Keywords
- Acceleration Data
- Box Girder Bridges
- Bridge Model
- Bridge Sites
- Cable Stayed Bridges
- Condition Assessments
- Design Earthquakes
- Emerson
- Factor Of Safety
- Finite Element Method
- Geologic Models
- Geometric Non-Linear
- H-Shaped
- Hollow Columns
- Mathematical Models
- Measured Data
- Mode Shapes
- Safety Factor
- Seismic Protective Systems
- Soil-Foundation-Structure Interactions
- Structural Control
- Structural Dynamics
- Three Dimensional Finite Element Model
Disciplines
- Civil Engineering
Fingerprint
Dive into the research topics of 'Condition Assessment of Bill Emerson Memorial Cable-Stayed Bridge under Postulated Design Earthquake'. Together they form a unique fingerprint.Cite this