Abstract
Novel explosive and conventional pulsed-power technologies were combined, and a series of explosive-driven high-voltage power supplies was designed, built, and tested. The power supply contained an explosive-driven high-voltage primary power source based on the fundamental physical effect of shockwave demagnetization of Nd 2 Fe 14 B high-energy ferromagnet and a power-conditioning stage. The volume of the energy-carrying ferromagnetic elements in the shockwave ferromagnetic generators (FMGs) was 8.75 cm 3 . The power-conditioning stage was based on the spiral vector inversion generator (VIG). The combined FMG-VIG system demonstrated successful operation and good performance. The output-voltage pulse amplitude of the combined FMG-VIG system exceeded 40 kV, with a rise time of 6.2 ns. The methodology was developed for digital simulation of the operation of completely explosive FMG-VIG system. Experimental results obtained are in a good agreement with the results of digital calculations performed.
| Original language | American English |
|---|---|
| Journal | IEEE Transactions on Plasma Science |
| Volume | 34 |
| DOIs | |
| State | Published - Jan 1 2006 |
Keywords
- Direct energy conversion
- Explosive pulsed power
- Hard ferromagnets
- Shockwave demagnetization
Disciplines
- Explosives Engineering
Fingerprint
Dive into the research topics of 'Completely Explosive Autonomous High-Voltage Pulsed-Power System Based on Shockwave Ferromagnetic Primary Power Source and Spiral Vector Inversion Generator'. Together they form a unique fingerprint.Cite this