Bioactive glasses may function as antimicrobial delivery systems through the incorporation and subsequent release of therapeutic ions. The aim of this study was to evaluate the antimicrobial properties of a series of composite scaffolds composed of poly (octanediol citrate) with increased loads of a bioactive glass that releases zinc (Zn 2+ ) and gallium (Ga 3+ ) ions in a controlled manner. The antibacterial activity of these scaffolds was investigated against both Gram-positive (Staphylococcus aureus) and Gram-negative (Escherichia coli) bacteria. The ability of the scaffolds to release ions and the subsequent ingress of these ions into hard tissue was evaluated using a bovine bone model. Scaffolds containing bioactive glass exhibited antibacterial activity and this increased in vitro with higher bioactive glass loads; viable cells decreased to about 20 % for the composite scaffold containing 30 % bioactive glass. The Ga 3+ release rate increased as a function of time and Zn 2+ was shown to incorporate into the surrounding bone.
| Original language | American English |
|---|---|
| Journal | Journal of Materials Science: Materials in Medicine |
| Volume | 27 |
| DOIs | |
| State | Published - Jan 1 2016 |
Disciplines
- Biochemical and Biomolecular Engineering
- Biomedical Devices and Instrumentation
- Chemical Engineering
Fingerprint
Dive into the research topics of 'Antibacterial Properties of Poly (Octanediol Citrate)/gallium-Containing Bioglass Composite Scaffolds'. Together they form a unique fingerprint.Cite this