Skip to main navigation Skip to search Skip to main content

An Inductive Probe for the Measurement of Common Mode Currents on Differential Traces

  • Missouri University of Science and Technology

Research output: Contribution to journal › Article › peer-review

Abstract

Measuring common mode currents on differential microstrip transmission lines is a complicated task, because the common mode current, being the parasitic mode, is usually much weaker than the intended differential current. Hence, the measurement technique has to provide sufficient rejection of the differential mode. The probe described in this paper uses a shielded loop probe combined with a metallic screen to enhance the differential mode rejection of the current probe. The proposed techniques were tested on a test board at frequencies up to 6 GHz.

Keywords

  • Current measurement
  • Magnetic field measurement
  • Metals
  • Microstrip
  • Power transmission lines
  • Probes
  • Transmission line measurements

Disciplines

  • Electrical and Computer Engineering

Fingerprint

Dive into the research topics of 'An Inductive Probe for the Measurement of Common Mode Currents on Differential Traces'. Together they form a unique fingerprint.